AFM Workshop

Atomic Force Microscope Manufacturer

Affordable Atomic Force Microscopes for Characterizing Polymer Materials

* <$70,000

 

Download the 2026 polymer AFM whitepaper (PDF)Affordable Atomic Force Microscopes for Characterizing Polymer Materials

 

Atomic force microscopy (AFM) provides quantitative, three-dimensional nanoscale characterization of polymers, including fibers, thin films, membranes and blends. AFMWorkshop offers complete, research-grade AFM systems designed for polymer characterization at a price range of approximately $40,000–$70,000, making in-house nanoscale analysis more accessible to research laboratories.

 

Table of Contents


1. Introduction
2. Why Use AFM for Polymer Characterization?
2.1. Key Advantages of AFM
2.2. Why Bring an Affordable AFM Into Your Laboratory?
3. Applications of AFM for imaging polymers
3.1. Polymer Fibers
3.2. Polymeric Organic Electronics
3.3. Thin Polymeric Films
3.4. Polymeric Membranes
3.5. Polymer Degradation
3.6. Characterizing Polymer Blends
4. AFM Solutions for Characterizing Polymer Materials
5. FAQs
6. References

 

 

1. Introduction

AFMWorkshop offers complete, research-grade atomic force microscope (AFM) systems priced between $40,000 and $70,000, making nanoscale characterization of polymer materials accessible to university, government, and industrial laboratories without sacrificing measurement quality.

Atomic force microscopy is a powerful technique for characterizing polymer materials because it provides three-dimensional surface measurements with nanometer-scale resolution while requiring little or no sample preparation. AFM can characterize both hard and soft materials in ambient air, liquids, and other environments, making it well suited for investigating polymer morphology, surface roughness, phase separation, degradation, thin films, fibers, membranes, and other advanced materials.

Historically, the cost of research-grade AFM instrumentation has limited its adoption in many laboratories, with conventional systems often priced between $125,000 and $400,000. AFMWorkshop’s approach to AFM design and manufacturing has reduced this cost substantially, providing complete research-grade systems in the $40,000 - $70,000 price range.

This white paper highlights published research by AFMWorkshop users demonstrating how AFM is being applied across a broad range of polymer investigations. The examples include characterization of polymer fibers, thin films, membranes, degradation processes, polymer blends, surface morphology, and other advanced polymer materials.

Together, these applications demonstrate how AFM provides quantitative nanoscale information that complements—and in many cases goes beyond—the information available from conventional optical microscopy and scanning electron microscopy (SEM).

 

2. Why Use AFM for Polymer Characterization?

AFM offers unique advantages that make it especially well-suited for polymer characterization.

AFM can generate quantitative three-dimensional surface maps with nanometer-scale vertical resolution, allowing researchers to measure roughness, feature height, pore depth, particle size, and other critical surface parameters directly from the acquired images. Because AFM does not require conductive coatings and typically involves minimal sample preparation, it is particularly effective for imaging delicate or electrically insulating polymer materials without altering their surface characteristics.

 

2.1 Key Advantages of AFM include:

  • Imaging of hard and soft polymers in ambient air or liquids
  • Minimal or no sample preparation
  • True three-dimensional quantitative measurements
  • Excellent contrast on smooth polymer surfaces
  • High vertical (sub-nanometer) resolution
  • Multiple imaging modes that reveal both topography and material properties
  • Electrical and mechanical property measurements using advanced AFM modes
  • Rapid operator training and straightforward quantitative analysis
Capability AFM SEM Optical
True 3D quantitative height data Yes, sub-nm vertical No - 2D projection No
Conductive coating required No Usually, for polymers No
Images in liquid Yes No Yes
Mechanical / phase contrast Yes - phase imaging No No
Resolution picometers nanometers micrometers
Typical system cost $40k - $70k*(*AFMWorkshop System) $70k - $500k $5k - $50k

2.2. Why Bring an Affordable AFM Into Your Laboratory?

Operating an AFMWorkshop system requires only a few hours of training. When maintained properly and used by trained operators, these systems demand little to no maintenance, making them a practical, low-overhead addition to any lab.

 

Benefits include:

  • Immediate Characterization
    Researchers can analyze samples immediately during material development rather than waiting for shared facilities.
  • Lower Operating Costs
    After purchase, AFM operating costs remain low, making AFM economical for routine characterization. Probe replacement is typically under $1,000 per year, eliminating recurring fees associated with contract services or shared facility usage.
  • Complete Control of R&D
    An in-house AFM allows faster process optimization, shorter development cycles, and continuous access to nanoscale measurements. You’re no longer dependent on external labs or oversubscribed core facilities, where delays and downtime are common. You gain consistent access, faster results, and greater autonomy over your R&D process.

 

3. Applications of AFM for imaging polymers

 

3.1. Polymer Fibers

AFM directly measures the three-dimensional morphology of polymer fibers while simultaneously providing quantitative information about fiber diameter, surface texture, and roughness. These measurements are valuable for development of electrospun materials, biomedical scaffolds, filtration media, and advanced composite reinforcements.

One advantage of AFM compared to, for example, electron microscopy is the ability to measure the three-dimensional shape of fibers (1). Figure 1 shows examples of three dimensional renderings of polymeric fibers, showing differences in texture between two different fiber samples, and highlighting the three-dimensional nature of the AFM images.

Polymer Fibers

Figure 1. Overlaid polymeric electrospun fibers visualized with the TT-AFM. The AFM images show the three-dimensional shape of the fibers and textural differences: fibers on the left-hand image are smoother than those on the right. Adapted from Cho et al. (2)

 

3.2. Polymeric Organic Electronics

AFM is an essential tool for characterizing polymeric organic electronic materials because it provides high-resolution measurements of surface morphology while preserving delicate polymer structures. Nanoscale surface morphology directly influences device performance. Unlike electron microscopy, AFM requires minimal sample preparation and can image soft polymer surfaces without altering their morphology. In addition to quantitative topography, advanced AFM modes enable in situ electrical measurements with nanoscale precision, allowing researchers to optimize the performance of organic electronic devices. AFMWorkshop systems have been widely used in the development of polymeric and organic electronics. (3,4,5,6,7)

 

3.3. Thin Polymeric Films

AFM is widely used to characterize thin polymer films because it directly measures surface morphology, roughness, grain structure, and film continuity. It is especially valuable for organic electronics, coatings, and functional polymer films where nanoscale surface features influence performance.

Thin polymer films can be characterized with AFM to determine film morphology. Organic electronics under development rely on production of homogeneous thin films. However, depending on deposition conditions films may form undesirable structures in the film, and AFM can be used to observe fine details of the produced films, greatly aiding development.

Images of different films produced in this way are shown in figure 2, showing how AFM differentiates between the varying micro- and nano-structures in these polymer films.

Polymeric Organic Electronics

Figure 2. AFM images of polymer films made up of poly(3-hexylthiophene), a polymer of interest for organic electronics. The AFM is able to clearly differentiate between the film structures of the three different samples produced under different conditions. Figure adapted from Gordon et al. (8)

 

3.4. Polymeric Membranes

AFM enables direct visualization of membrane pore size, pore distribution, and surface roughness. These measurements are critical for optimizing membranes used in vital processes such as safe drinking and waste water filtration, desalination, the manufacture of high-performance batteries, and biomedical devices.

An example of this is shown in figure 3, which shows two membranes, both made from polycaprolactone but in which the inclusion of nanoparticles in the polymer membrane leads to a radical change in pore shape and size, and a roughening of membrane surface. Indeed, membrane roughness has been measured using AFM in a number of different systems. (9,10,11,12)

Polymeric Membranes

Figure 3. Images of two polymeric membranes showing the difference in structure when nanoparticles are included (right), compared to the simple membrane (left). In the left image, the pores are reproducible in format, compared to the highly variable shape in the membrane on the right. Quantitatively, the nanoparticle - containing membrane was also shown by the AFM to be significantly rougher. Images provided compliments of the author. Original work published in: M.H. Mruthunjayappa et al.(12)

AFM is particularly well suited for characterizing electrically insulating polymer membranes, which can be difficult to analyze using electron microscopy. By providing quantitative three-dimensional measurements of surface roughness, pore morphology, and membrane structure with minimal sample preparation, AFM enables researchers to optimize membrane performance across a wide range of applications. AFMWorkshop systems have been used to characterize polymeric membranes for lithium-ion batteries (13, 14). AFM is also useful to characterize polymeric membranes under development for desalination (9) and distillation (15), as well as for general filtration, especially nanofiltration (16), where the ultrahigh resolution of AFM makes it an indispensable tool.

 

3.5. Polymer Degradation

AFM provides a quantitative method for monitoring polymer degradation by measuring changes in surface roughness and morphology over time. Unlike many imaging techniques, AFM produces numerical roughness values that can be directly correlated with weathering, abrasion, or chemical exposure. (14,17,18)

Figure 4 shows the effect of exposure to sand abrasion over several days on two different polymers. Displaying the images on the same scale makes the effect of weathering very clear. Roughness values can also be used to quantify the effect. In this case, roughness initially increased upon weathering and then decreased with more weathering due to a filling-in effect. In a similar way degradation of polymeric dental materials has been analyzed with AFM, after exposure to acidic drinks (18).

Polymer Degradation

Figure 4. AFM height images showing the effect of abrasion by sand on a PET plastic surface. Images adapted from Aghilinasrollahabadi et al. (19)

 

3.6. Characterizing Polymer Blends

AFM phase imaging enables researchers to distinguish and measure individual polymer domains in polymer blends by detecting differences in stiffness and viscoelastic behavior, providing quantitative information about blend morphology, domain size, and distribution.

Phase imaging is particularly useful for characterizing polymer blends because differences in the mechanical and viscoelastic properties of the constituent polymers produce measurable phase contrast. This contrast allows researchers to visualize the distribution and morphology of individual polymer phases at the nanoscale.

Polypropylene (PP) and polyethylene (PE) blends illustrate this application. Because PP and PE have significantly different elastic moduli and viscoelastic properties, the AFM probe experiences distinct phase shifts as it interacts with each polymer, producing contrast between the two phases.

  • 75% PP / 25% PE Blend -In a 75% PP / 25% PE blend, phase imaging typically reveals a continuous matrix of the stiffer polypropylene containing discrete, circular domains of softer polyethylene. AFM phase imaging provides clear contrast between the two polymers, allowing researchers to characterize domain size, shape, and distribution—properties that can influence the blend’s mechanical performance, including impact resistance.
  • 50/50 PP / PE Blend - As the composition approaches a 50/50 ratio, the morphology can transition from a “sea-island” structure to a co-continuous network. Phase imaging enables researchers to visualize the complex interpenetrating structures of the two polymers and evaluate how mixing conditions and thermal history influence the final morphology and structural integrity.
Characterizing Polymer Blends

Figure 5. Circular phase domains in a 75% PP / 25% PE blend showing many features in the phase image not visible in the height data.

A: topography, 20x20 μm scan, height scale 177 nm and

B: corresponding phase image.

C: topography, 8x8 μm scan, height scale 232 nm and

D: corresponding phase image.

Optimizing Polymer Blend Performance

AFM phase imaging can help researchers evaluate compatibilizers and optimize polymer-processing parameters by directly visualizing changes in nanoscale blend morphology. This information can be used to develop polymer blends with targeted mechanical properties and improved performance.

 

4. AFM Solutions for Polymer Research

AFMWorkshop offers high-performance AFMs that are robust, intuitive to use, and affordable for a wide range of laboratories. Our innovative AFM designs emphasize the features most important for scanning polymeric materials, without the added complexity and cost of unnecessary features often found in higher-priced systems.

The images presented in this white paper were measured by AFMWorkshop customers primarily using the TT-2 AFM and HR AFM.

TT-2 AFM

The TT-2 AFM combines research-grade performance with exceptional flexibility.

Its low noise floor, direct-drive tip approach, integrated optical microscope, and modular architecture provide high-resolution imaging for a wide range of samples and applications. Easy probe exchange, compatibility with probes from all major manufacturers, and customizable LabVIEW® software make the TT-2 an adaptable platform that grows with research needs.

HR AFM

The HR AFM is designed for researchers who require the highest resolution and measurement precision.

Featuring an ultra-low 35 pm noise floor, precision kinematic tip approach, integrated top- and side-view optics, and multiple scanner options, it delivers exceptional imaging performance across a wide range of applications. Its modular design, rapid probe exchange, broad probe compatibility, and customizable LabVIEW® software provide a flexible platform that grows with your research needs.

HR AFM

 

The HR AFM includes the AFM Stage, control electronics, and software for high resolution scanning.
AFMWorkshop offers several vibration solutions, and installation packages.

 

5. FAQs

 

How much does an atomic force microscope cost?

Research-grade AFMs have historically cost $125,000 to $400,000. AFMWorkshop supplies complete research- grade systems for $40,000 to $70,000, with probe replacement typically under $1,000 per year.

 

Why use AFM instead of SEM for polymers?

AFM gives true three-dimensional quantitative measurements with sub-nanometer vertical resolution, needs no conductive coating, and images soft or electrically insulating polymers in air or liquid without altering them.

 

Which AFM mode is used to characterize polymer blends?

AFM phase imaging mode is preferred for polymer blends. Differences in stiffness and viscoelasticity produce phase contrast that separates domains — for example a continuous polypropylene matrix with discrete polyethylene domains in a 75/25 PP/PE blend

 

How long does it take to train an operator on an AFM?

Operating an AFMWorkshop system requires only a few hours of training, and properly maintained systems need little to no maintenance.

 

6. References

  1. Youn, D.-H., Lee, K.-S., Jung, S.-K., & Kang, M. (2021). Fabrication of a Simultaneous Highly Transparent and Highly Hydrophobic Fibrous Films. Applied Sciences, 11(12), 5565.
    DOI: https://doi.org/10.3390/app11125565
  2. Cho, H., Madhurakkat Perikamana, S. K., Lee, J., Lee, J., Lee, K.-M., Shin, C. S., & Shin, H. (2014). Effective Immobilization of BMP-2 Mediated by Polydopamine Coating on Biodegradable Nanofibers for Enhanced in Vivo Bone Formation. ACS Applied Materials & Interfaces, 6(14), 11225–11235.
    DOI: https://doi.org/10.1021/am501391z
  3. Lee, H., Lee, S., Cha, S., Anoop, G., & Shin, H. (2025). Nanoscale Electron Beam Patterning of PEDOT : PSS Free‐Standing Films for Enhanced Thermoelectric Performance. ENERGY & ENVIRONMENTAL MATERIALS, 8(2).
    DOI: https://doi.org/10.1002/eem2.12824
  4. Laventure, A., Brixi, S., Welch, G. C., & Lessard, B. H. (2024). Stability assessment of PTB7‐Th and a quinoxaline‐based polymer in both organic thin film transistors and in organic photovoltaic devices. The Canadian Journal of Chemical Engineering, 102(12), 4129–4136.
    DOI: https://doi.org/10.1002/cjce.25464
  5. Kim, S. H., Sun, C., Saeed, M. A., Kwon, H.-J., Kim, T. H., Kwon, S.-K., Kim, Y.-H., & Shim, J. W. (2023). Fine-tuning of the inner sidechain of donor polymers for efficient indoor organic photovoltaics. Journal of Materials Chemistry A, 11(23), 12130–12139.
    DOI: https://doi.org/10.1039/D3TA00293D
  6. Kim, S. H., Park, C. H., Saeed, M. A., Ko, D.-H., Lee, J.-H., & Shim, J. W. (2022). β-cyclodextrin–polyacryloyl hydrazide-based surface modification for efficient electron-collecting electrodes of indoor organic photovoltaics. Journal of Materials Research and Technology, 16, 1659–1666.
    DOI: https://doi.org/10.1016/j.jmrt.2021.12.086
  7. Iwan, A., Caballero-Briones, F., A. Bogdanowicz, K., D. O. Barceinas- Sánchez, J., Przybyl, W., Januszko, A., A. Baron-Miranda, J., P. Espinosa-Ramirez, A., & Guerrero-Contreras, J. (2018). Optical and electrical properties of graphene oxide and reduced graphene oxide films deposited onto glass and Ecoflex® substrates towards organic solar cells. Advanced Materials Letters, 9(1), 58–65.
    DOI: https://doi.org/10.5185/amlett.2018.1870
  8. Gordon, M. P., Lloyd, L. T., & Boucher, D. S. (2016). Poly(3‐ hexylthiophene) films prepared using binary solvent mixtures. Journal of Polymer Science Part B: Polymer Physics, 54(6), 624–638.
    DOI: https://doi.org/10.1002/polb.23923
  9. Perera, M. G. N., Galagedara, Y. R., Ren, Y., Jayaweera, M., Zhao, Y., & Weerasooriya, R. (2018). Fabrication of fullerenol-incorporated thin-film nanocomposite forward osmosis membranes for improved desalination performances. Journal of Polymer Research, 25(9), 199.
    DOI: https://doi.org/10.1007/s10965-018-1593-4
  1. Wang, K., Seol, H., Cheng, A., McKeague, N., Carlson, M., Degraff, W., Huang, S., & Kim, S. (2023). Simple Bioparticle Filtration Device Based on an Ultralow-Fouling Zwitterionic Polyurethane Membrane for Rapid Large-Volume Separation of Plasma and Viruses from Whole Blood. Membranes, 13(5), 524.
    DOI: https://doi.org/10.3390/membranes13050524
  2. Awad Abouelata, A. M., Abdallah, S. M. A., Sorour, M. H., Shawky, N. A., & Abdel‐Fatah, M. A. (2020). Modification and ionic stimulation of hollow fiber membrane by electric field for water treatment. Journal of Applied Polymer Science, 137(39).
    DOI: https://doi.org/10.1002/app.49190
  3. Halanur Mruthunjayappa, M., Shachar, C., Imbar, A., Menashe, O. A., & Mamane, H. (2024). Cellulose acetate and polycaprolactone based photoactive ultrafiltration membrane: A novel approach with UV-switchable photocatalytic activity. Separation and Purification Technology, 329, 125102.
    DOI: https://doi.org/10.1016/j.seppur.2023.125102
  4. Wang, T., Wang, X., Pendse, A., Gao, Y., Wang, K., Bae, C., & Kim, S. (2021). High-efficient multifunctional electrochemical membrane for lithium polysulfide redox flow batteries. Journal of Membrane Science, 636, 119539.
    DOI: https://doi.org/10.1016/j.memsci.2021.119539
  5. Wang, T., Lee, J., Wang, X., Wang, K., Bae, C., & Kim, S. (2022). Surface‐engineered Nafion/CNTs nanocomposite membrane with improved voltage efficiency for vanadium redox flow battery. Journal of Applied Polymer Science, 139(7).
    DOI: https://doi.org/10.1002/app.51628
  6. Woo, Y. C., Tijing, L. D., Shim, W.-G., Choi, J.-S., Kim, S.-H., He, T., Drioli, E., & Shon, H. K. (2016). Water desalination using graphene-enhanced electrospun nanofiber membrane via air gap membrane distillation. Journal of Membrane Science, 520, 99–110.
    DOI: https://doi.org/10.1016/j.memsci.2016.07.049
  7. Morales‐Cuevas, J. B., Pérez‐Sicairos, S., Lin, S. W., & Salazar‐ Gastélum, M. I. (2019). Evaluation of a modified spray‐applied interfacial polymerization method for preparation of nanofiltration membranes. Journal of Applied Polymer Science, 136(42).
    DOI: https://doi.org/10.1002/app.48129
  8. Blourchian, A., Shaik, A. M., Huynh, N. U., & Youssef, G. (2021). Segmental evolution of ultraviolet weathered polyurea. Journal of Polymer Research, 28(4).
    DOI: https://doi.org/10.1007/s10965-021-02483-4
  9. Ahmed, R. S., & Saleem, A. I. (2022). Evaluation of the Effect of Natural and Industrial Orange Juices and Beverage on Surface Roughness of Orthodontic Bonding Composite. Dental Hypotheses, 13(3), 107–110.
    DOI: https://doi.org/10.4103/denthyp.denthyp_76_22
  10. Aghilinasrollahabadi, K., Salehi, M., & Fujiwara, T. (2021). Investigate the influence of microplastics weathering on their heavy metals uptake in stormwater. Journal of Hazardous Materials, 408, 124439.
    DOI: https://doi.org/10.1016/j.jhazmat.2020.124439

 

See additional images of polymers from AFMWorkshop AFMs here.

 

Subscribe to our Newsletter

Invalid email address.

×

TOP